MIC-2000DX multipurpose surgical operating microscope
Neurosurgery microscope Brain surgery microscope ENT surgical microscope Dental operating microscope Ophtalmology surgical microscope Oral surgical microscope Orthopedic surgery microscope, Hand surgery microscope The cosmetic skin Branch surgical microscope Family planning microscope Eye surgery microscope Eye orthopaedic surgery microscope Gynecological vaginal microscope colposcope, Video image acquisition system workstations
The product is an advanced double binocular operation microscope designed for two operators, with the illumination source of 100W medical Xenon lamp and -2°+6°coaxial illumination.It is applicable in various complicated operations.
Features
◆ It provides an amazingly clear, fine observations by using Xenon light source.
◆ -2°~+6° coaxial illumination greatly improves the intensity and range of red light reflex.
◆ UV-proof and heat absorption reduces the harm to intraocular tissues and make the patient feel more comfortable.
◆ Schott optics ensure the surgeons a bright, balanced and fine observation.
◆ Apochromatic technology is used in the optical design to ensures coaxial light focus and makes a clearer field of view.
Specifications
Objective focus range (mm) | Standard F=215 | |||||
Working distance (mm) | 170mm | |||||
Total MAG. | Main lens | 4.6x~27x | Assistant lens | 6x / 10x / 14x | ||
N.A. | Main lens | 0.014~0.043 | Assistant lens | 0.021 / 0.033 / 0.0375 | ||
Filed of view diameter(mm) | 4.6x~F46 27x~F8.5 | |||||
Main lens zoom ratio | 1:6 | |||||
Coaxial illumination | Range | ≥F45(F=215mm) | ||||
Model | -2°+6° Coaxial illumination | 26° Oblique illumination | ||||
Fine focus range | ≥40mm | |||||
Speed of fine focus (adjustable) | ≤2mm/s | |||||
X-Y moving range) | 50mm×50mm | X- ← 0~-25;Home position0;X+ → 0~+25 | ||||
Y- ↓ 0~-25;Home position0;Y+ ↑ 0~+25 | ||||||
X-Y moving speed(adjustable) | ≤2mm/s | |||||
Filter
|
Inner fixed | UV、IR:
wavelength=700~850nm,transmittance ratio T≤1% wavelength=415~680nm,transmittance ratio T≥90% |
Move infrared, ultraviolet light, alleviating damage from the light to the patients | |||
Optional | Black point filter: no transmitting in the middle Φ2.5 | Form black point in the light path, avoiding burning to the retina | ||||
No red filter wavelength=415~580nm,transmittance ratio T≥90%
wavelength=595~680nm,transmittance ratio T≤1% |
Move all red light over 580nm wavelength, decreasing the influence to the image clearance caused by the blood red color | |||||
GG435:
wavelength=350~435nm,transmittance ratio T≤1% wavelength=425~675nm,reflectance ratio R≤0.5% |
Decreasing the short wavelength light energy, avoiding light induced corneal injury | |||||
GG475:
wavelength=350~475nm,transmittance ratio T≤1% wavelength=425~675nm,reflectance ratio R≤0.5% |
Decreasing the blue light energy, avoiding light induced retinitis. | |||||
CCD optional adapter | 1/3CCD, standard C interface |